| NetApp FAS3020 Filers | The newly introduced FAS3000 series has the potential to deliver exceptional storage value for midtier enterprise data centers and medium-sized businesses, including use for database applications, e-mail, and network storage shares. Its compact, modular design delivers integrated FC SAN, iSCSI, and NAS data serving in dual active-active systems scaling to 84TB. The FAS3020 is capable of providing superb storage price/performance for smaller data centers, midsized business, and large department deployments. Download FAS30X0 Series - Technical Specifications (PDF 124KB) If you would like more information on the product please contact our sales department by sending an email to sales@berkcom.com or by calling us at (877) BERKCOM. | | LEARN MORE ABOUT |
FAS3070 Filers The FAS3070 is at the "top of the midrange," according to Rich Clifton, vice president and general manager of NetApp...
FAS3050 Filers The FAS3050 delivers the performance, flexibility, and manageability essential to stable and productive IT operation....
FAS3040 Filers Excellent performance and lower TCO.
| | |
| FAS3020 Technical Highlights |
| Maximum RAID Group Sizes |
RAID-6 (RAID-DP)
FC-28 (26 data disks plus 2 parity disks)
SATA-16 (14 data disks plus 2 parity disks)
RAID-4
FC-14 (13 data disks plus 1 parity disk)
SATA-7 (6 data disks plus 1 parity disk)
RAID-6+RAID1 or RAID4+RAID1 (SyncMirror) |
| SAN Protocol Support |
Fibre Channel Protocol (FCP) for SCSI (2Gb and 4Gb); fabric-attached and direct-attached; iSCSI |
| File Service Protocol Support |
NFS V2/V3/V4 over UDP or TCP, PCNFSD V1/V2 for (PC) NFS client authentication, Microsoft CIFS |
| Other Protocol Support |
HTTP 1.0, HTTP 1.1 virtual hosts |
| LUNs |
Up to 2,048 on FAS3070 and up to 1,024 on FAS3020 and FAS3050 |
| FlexVol Volumes |
Up to 500 per controller |
| Volume/Aggregate Size |
16TB |
| Snapshot Copies |
Up to 127,000 |
| Number of Supported Hosts |
Up to 4 ports per controller configured as front-end (host) connectivity ports
Up to 4 directly connected servers (per controller and per active/active configuration)
Up to 256 SAN connected servers (per controller and per active/active configuration) |
| Supported Configurations |
Highly Available Controller Configurations
Active/active controller with Controller Failover (CFO), active/active controller with stretch (non-switch) MetroCluster, active/active controller with Fabric Attached MetroCluster
Highly Available Back-End (Disk) Configurations
Dual-path, Multipath HA Storage |
| Reliability |
Redundant hot-swappable controllers, cooling fans, power supplies, optics, and RJ-45 ports |
| Management |
Full-duplex 10/100/1000Base-T Ethernet onboard console, diagnostic LED/LCD, Remote LAN Management (RLM) Card, SNMP, telnet, SSH, HTTP, Web (SSL), host scripting, e-mail alerts |
| Security |
Virus Protection
Authentication: Kerberos (MIT/Active Directory)
Authorization: LDAP, NIS
Auditing: File access logging
Encryption: IPSec, SSL, SSH, SMB signing
Role Based Access Control (RBAC) |
| Scalability |
FAS3020 |
| |
Active/Active
Configuration |
Single
Controller |
| Max. Raw Capacity |
84TB |
84TB |
| Max. Number of Disk Drives |
168 |
168 |
| Max. Drives per Back-End (Disk) FC Loop |
84 |
84 |
| ECC Memory |
4GB |
2GB |
| Nonvolatile Memory |
1GB |
512MB |
| I/O |
FAS3020 |
| |
Active/Active
Configuration |
Single
Controller |
| Onboard (fixed) Fibre Channel Ports (target or initiator) |
8 ports of 2Gb |
4 ports of 2Gb |
| Onboard (fixed) GbE Ports |
8 |
4 |
| Modular I/O Slots |
6 |
3 |
RAID-6 is the recommended configuration for drives greater than 144 GB.
RLM module is an optional capability on the FAS3020 that is included at no charge with SupportEdge Premium contract.
|
| I/O Card Support |
FAS3020 |
| |
Active/Active
Configuration |
Single
Controller |
| Dual FC Disk Adapters (max.) |
6 |
3 |
| Dual 4Gb FC Target Adapters (max.) |
4 |
2 |
| Quad 4Gb FC Disk/Tape Adapters (max.) |
6 |
3 |
| Dual FC -Tape Adapters (max.) |
6 |
3 |
| Dual-port SCSI HBA |
6 |
3 |
Optional Network Connectivity (max.)
Quad GbE TOE (copper) cards
Single 10GbE TOE (fiber) cards
Dual GbE (copper or fiber) cards
Dual iSCSI (copper or fiber) host adapter
|
4
4
6
6 |
2
2
3
3 |
| Sofware |
| Operating System |
Network Appliance Data ONTAP |
| Operating Systems Supported |
Windows 2000, Windows Server 2003, Windows XP, Linux, Sun Solaris, AIX, HP-UX, Mac OS, VMware, ESX |
| Software Features |
Standard
RAID manager, including RAID-6 (RAID-DP)
Snapshot
Fast Boot
NIS
DNS
FilerView
FlexVol
FlexCache
FlexShare
Network Data Management Protocol (NDMP)
Maintenance Center
|
Licensed
FlexClone
MultiStore
SnapMirror
SnapRestore
SnapDrive
SnapManager for Microsoft Exchange
SnapManager for Microsoft SQL Server
SnapManager for Oracle
Single Mailbox Recovery
SnapVault
SnapMover
LockVault
SnapLock Compliance
SnapLock Enterprise
SyncMirror
MetroCluster
NearStore Personality Option
CommandCentral Storage
Protection Manager
Virtual File Manager - Enterprise Edition
Virtual File Manager - Migration Edition
File Storage Resource Manager
SAN Manager
Operations Manager
ApplianceWatch for HP Openview
ApplianceWatch for Tivoli |
| Storage Specifications |
| Disk Shelves Supported (Fibre Channel, SATA) |
DS14, DS14mk2 FC, DS14mk2AT
Each w/14 low-profile slots for FC and SATA disk drives |
| Disk Drive Support |
Disks Supported on New Configurations
FC-144GB, 300GB disks
SATA-250GB, 500GB disks
Disks Supported for Legacy (Controller Upgrade) Configurations
FC-36GB, 72GB, 144GB, 300GB disks
SATA-250GB, 320GB, 500GB disks |
| Disk Shelf Support |
Shelves Supported on New Configurations
Embedded Switched Hub (ESH)
Embedded Switched Hub2 (ESH2)
AT-FCX
Shelves Supported for Legacy (Controller Upgrade) Configurations
Embedded Switched Hub (ESH)
Embedded Switched Hub2 (ESH2)
AT-FCX
LRC |
| Disk Drive Storage Shelf Interface |
Fibre Channel-Arbitrated Loop (FC-AL) |
| Power Supply/Cooling Fans |
Dual, redundant, hot-pluggable, integrated power supply/fan assemblies (220V/110V) |
| AC Power/Max. Current |
100 to 120VAC/3.95A; 200 to 240VAC/1.9A |
| Thermal Rating |
1,215 Btu/hr (fully loaded shelf) |
| Operating Acoustic Noise |
49 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level) |
| Dimensions (height/width/depth) |
3 EIA U (5.25", 13.3 cm)/19" IEC rack-compliant (17.6", 44.7 cm)/20" (50.85 cm) |
| Weight |
77 lb (35 kg) fully loaded |
FAS3020 has PCI-x I/O slots.
Protection Manager was previously known as Business Continuance Option
Operations Manager was previously known as Data Fabric Manager (DFM). |
| FC Switch Support- Tape/SAN |
| Vendor |
Model |
| Brocade |
Silkworm 2400/2800 (TapeSAN only) |
| Brocade |
Silkworm 3200/3250/3800/3850/3900/4100/12000/24000/200E |
| McData |
ES 3016/3032, Intrepid 6064/6140/ED-5000, Sphereon 3216/3232/4300/4400/4500/4700 |
| Cisco |
MDS 9120/9140/9216/9506/9509/9513 |
| FC = Fibre Channel; LVD = Low Voltage Differential |
| NetApp Systems Cabinet |
20A and 30A single phase cabinets.
20A Cabinet - Includes 4 power cords with NEMA L6-20 or IEC 309 or Australia AS/NZ53123-20 connectors
30A Cabinet - Includes 2 power cords with NEMA L6-30 or IEC 309 connectors |
20A Cabinet - a single controller and 13 DS-14 shelves; two controllers and 12 DS-14 shelves
30A Cabinet - a single controller and 12 DS-14 shelves; two controllers and 11 DS-14 shelves |
| AC Power |
200 to 240VAC |
| Current |
Redundant power
20A Cabinet - Maximum 32A total
30A Cabinet - Maximum 24A total |
| Dimensions (height/width/depth) |
78.75" (200 cm)/23.6" (60 cm)/37.4" (95 cm) |
| Min. Clearances |
48" (122 cm) front and rear |
| Shipping Height |
90.6" (230 cm) |
| Weight (empty) |
275 lb (125 kg) |
| FAS System
Specifications |
Active/Active
Configuration |
Single Controller
Configuration |
| AC and DC Power/Current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240VAC only) |
100 to 240VAC, 7.66 to 3.50A, 50/60Hz
200 to 240VAC, 4.00 to 3.50A, 50/60Hz
48VDC, 14.8A, 710W |
100 to 240VAC, 3.83 to 1.75A, 50/60Hz
200 to 240VAC, 2.00 to 1.75A, 50/60Hz
48VDC, 7.4A, 355W |
| Thermal Rating |
2430 Btu/hr |
1215 Btu/hr (note: Watts x 3.4129) |
| Weight |
150 lb (68 kg) |
75 lb (34 kg) |
| Height |
10.24" (26 cm), fits into 6U space |
5.12" (13 cm), fits into 3U space |
| Width |
19" IEC rack-compliant (17.7", 44.9 cm) |
| Depth |
24" (61 cm), 30" (76.2 cm) with cable management bracket |
| Operating Temperature, Altitude, and Relative Humidity |
10° C to 40° C (50° F to 104° F); at </= 3,000 m (at </= 10,000') elevation; 20% to 80% relative humidity, non-condensing (28° C wet bulb temperature) |
| Non-operating Temperature and Relative Humidity |
-40° C to 65° C (-40° F to 149° F); 10% to 95% relative humidity, non-condensing, in original container |
| Operating Acoustic Noise |
< 54 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level) |
| Min. Cabinet Clearances for Airflow |
10" (25.4 cm) in front, 12" (30.5 cm) in rear |
| Min. Cabinet Clearances for Service |
30" (76.2 cm ) in front, 30" (76.2 cm) in rear |
| Compliance |
RoHS-compliant |
| Safety/Emissions/Immunity |
Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, IRAM, GOST-R, BSMI
Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, MIC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3, CoC (South Africa), BSMI |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(877) BERKCOM |